Model Q46C2 2E Conductivity Monitor

Brand: Analytical Technology Inc

Low-level Conductivity measurements are essential for a variety of water quality monitoring. 

The proper operation of deionizers, reverse osmosis membranes, ion exchange systems, and heat exchangers require constant monitoring to ensure high quality production.

ATi’s Q46C2 2E Conductivity monitor provides large, easy-to-read LCD displays with a second display line for indication of temperature or other operational information. 

And for those applications where results in resistivity units are preferred, Q46C2 monitors can be programmed to display readings in Meg-ohm units instead of microSiemens.

Q46C2 conductivity monitors can also be configured to measure and display the concentration of chemicals used in various process applications. 

For applications where there are several chemicals dissolved in solution, the Q46C2 monitor can be configured to measure and display the concentration of total dissolved solids (TDS). 

Temperature compensation can either be made by custom compensation table or a single linear compensation factor.
Features
  • Adaptable – Available in a Concentration version for direct display of chemical concentrations and for Total Dissolved Solids.
  • Customized Response with a user configurable table for a custom concentration curve.
  • Analog Output Options
  • Additional Outputs – Expansion board to add a third 4-20 mA analog output
  • AC or DC Power Options
  • PID Output – Standard PID control function assignable to one analog output.
  • Digital Communications options for Profibus-DP, Modbus-RTU, or Ethernet-IP
  • Three SPDT relays are standard, with relay functions programmable for alarm, control, or trouble indication. Three additional low power relays available as an option.
  • Flexible Mounting Large, clear Display

Specifications

Display Range

  • 0-2.000 / 20.00 / 200.0 / 2000 μS

Accuracy

  • 0.1 % of Selected Range

Repeatability

  • 0.1 % of Selected Range

Non-Linearity

  • 0.1 % of Selected Range

Temperature Drift

  • 0.03 % of Span/°C

Power

  • 100-240 Vac ± 10 %, 50/60 Hz, 10 VA Max.
  • 12-24 Vdc, 500 mA Max.

Analog Outputs

  • Two Isolated 4-20 mA, 500 Ω Load Max. (3rd Output Optional)

Relays

  • Three SPDT, Contacts Rated 6 amp @ 250 Vac, 5 amp @ 24 Vdc (3 Additional Low Power SPST Non-Isolated Relays Optional)

Display

  • 4 Digit, 0.75” Numeric LCD with 12 Character Second Line, LED back light.

Enclosure

  • NEMA 4X Polycarbonate V-0 Flammability

Operating Conditions

  • -20 to 60° C (-4 to 140° F)

Weight

  • 6 lbs (2.7 kg) with Sensor

Sensitivity

  • 0.05 % of Span

Digital Output

  • Profibus-DP, Modbus-RTU, or Ethernet-IP

Mounting

  • Wall Mounting Kit Standard, Panel Mount Bracket and Pipe U-Bolts Available

Size

  • 5.6” W x 4.9” H x 6.4” D

Sensor Type

  • 2-Electrode

Sensor Materials

  • Titanium, PEEK

Sensor Cable Length

  • 15 ft (4.6 m) Standard, 60 ft (18.3 m) Max. with Junction Box

Sensor Temperature Limits

  • 0-125° C

Sensor Pressure Limit

  • 100 psig Max.

Connection

  • 1/2” NPT or 1-1/2” Stanitary-Style

Temperature Element

  • Pt1000 RTD

  • Low-level conductivity measurements are essential for monitoring a variety of high purity water systems
  • Operation of deionizers, reverse osmosis membranes, ion exchange systems and heat exchangers
  • Low-level measurements for high purity water systems

show more