Approvals & Certifications
- ISO 9001 (DQS)
- QPS (C, US)
Approvals & Certifications
- CE
- EMC Electromagnetic Emission EN 61000-6-3, Immunity EN 61000-6-2
- UL 61010-1
Consumption
- Current Consumption: 50-140 mA
Electrical Connectors
- M12 (5-Pin) Male Connector
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
- Sensor Electronics: AISI 316L Stainless Steel, 1.4404
Environmental Protection
- Ingress Protection: IP67
- Ingress Protection: IP69K (If Mating Cable Connector is Correctly Fitted)
Humidity
- 90 % Relative Humidity, Non-Condensing
Length
- Stroke Length: 2 to 100” (50 to 2,540 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)
Load
- 0 to 500 ohms for Current Output
Materials of Construction
- Sensor Rod 10 mm (0.39”) Rod-Ø : AISI 304L Stainless Steel 1.4306
- Sensor Rod 7 mm (0.28”) Rod-Ø : AISI 304 Stainless Steel 1.4301
- Sensor Rod: AISI 316L Stainless Steel, 1.4404
Operating Pressure
- 0.28” (7 mm) Rod-Ø psi: 4,351 to 6,527 (kPa: 30,000 to 45,000, bar: 300 to 450) Peak
- 0.39” (10 mm) Rod-Ø psi: 5,076 to 7,687 (kPa: 35,000 to 53,000, bar: 350 to 530) Peak
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Output
- 0-10 Vdc
- 10-0 Vdc
- 20-4 mA
- 4-20 mA
Principle of Operation
- Magnetostrictive Principle
Repeatability
- ≤ ± 0.005 % of Full Scale (Min. ± 20 µm)
Resistance
- Controller Input Resistance: > 5 kiloohms for Voltage Output
Shock
- 100 G (Single Shock) IEC 60068-2-27
Vibration
- 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage