Approvals & Certifications
- ISO 9001 (DQS)
- CE
- EMC Electromagnetic Emission EN 61000-6-4, Immunity EN 61000-6-2
Cable Length
- 3 to 33 feet (1 to 10 metres)
Consumption
- Current Consumption: 100 mA Typically Dependent on Stroke Length
Electrical Connectors
- M12 Male A-Coded (5-Pin) Connector
- M16 (6-Pin) Connector Male
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
Environmental Protection
- Ingress Protection: IP67 with Proper Mating Connector
- Ingress Protection: IP68 for Cable Outlet
Length
- Stroke Length: 1 to 128” (25 to 3,250 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm) Typical
Load
- Minimum Load Controller: > 5 kiloohms for Voltage Output
- Minimum/Max.imum
Materials of Construction
- Sensor Rod: 304L Stainless Steel 1.4306, 1.4307
Operating Pressure
- psi: 10,153 (kPa: 70,000, bar: 700) Peak (At 10 x 1 Min)
- psi: 5,076 (kPa: 35,000, bar: 350)
Operating Temperature
- -40° to 90° C (-40° to 194° F)
- Option: -40° to 100° C (-40° to 212° F)
Output
- 0-10 Vdc
- 0-20 mA
- 10-0 Vdc
- 20-0 mA
- 20-4 mA
- 4-20 mA
Repeatability
- ≤ ± 0.005 % of Full Scale (Min. ± 20 µm) Typical
Resolution
- 16-bits (Min. 1 µm Depending on Stroke Length)
Shock
- 100 G (Single Shock) IEC 60068-2-27
Vibration
- 15 G (10 to 2,000 Hz) IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 500 Vdc (DC Ground to Machine Ground)