131/141 Differential Pressure Switch
Brand: SOR Inc131/141 differential pressure switches are robust field-mounted instruments. 
The 131/141 pressure sensing assembly is a diaphragm-piston combination. Switching elements are SPDT or DPDT.
Features- Built-In Quality - Rigid quality standards maintained from raw material to finished product.
 - Complete Product Line - Standard models with many options cover pressure range 5" wcd to psi: 180 (kPa: 1,241, bar: 12.4)
 - Instrument Quality - High repeatability, narrow dead band, negligible temperature effect and long-term stability
 - Field Adjustable - Excellent resolution of Set Points, self-locking adjustment, no special tools required
 - Construction - Rugged, long life, not critical to vibration, high static pressures, low differential pressures, excellent corrosion resistance to hostile environments
 
Specifications
Brand
Adjustment Type
- Field Adjustable
 
Ambient Temperature Range
- -34° to 108° C (-30° to 227° F)
 
Deadband
- psi: 0.18 to 10.8 (kPa: 1.2 to 74.7, bar: 0.01 to 0.7)
 
Diaphragm Material
- 316L Stainless Steel
 
Differential Pressure
- psi: 0 to 300 (kPa: 0 to 2,100, bar: 0 to 21) - Max.
 
Electrical Connectors
- Conduit Seal Connector with 17 feet Lead Wire Length
 
Electrical Rating
- 0.3 A at 125 Vdc
 - 5 A at 250 Vac Resistive
 
Enclosure, Body Material
- Carbon Steel
 
Materials of Construction
- Mounting: Stainless Steel
 
Maximum System Pressure
- psi: 1,850 (kPa: 12,500, bar: 125)
 
Mounting
- Mounting Bracket
 
Name Plate, Tag Material
- Stainless Steel
 
NPT Connection
- Pressure Port: 1/4" NPT Female
 
O-Ring Material
- EPR at -34° to 93° C (-30° to 200° F)
 
Pressure Type
- Differential
 
Process Connection Material
- 316 Stainless Steel
 
Repeatability
- ± 1 % of Full Scale as Defined by ANSI / ISA S51.1
 
Seat / Seal Material
- Seal: Ethylene Propylene (EPR)
 
Set Point - Decreasing
- bar: 0.01 to 12.41
 - inH₂O: 5 to 300
 - kPa: 1.2 to 1241.1
 - psi: 0.18 to 180
 
Set Point - Increasing
- bar: 0.01 to 12.41
 - inH₂O: 5 to 300
 - kPa: 1.2 to 1241.1
 - psi: 0.18 to 180
 
Switch Type
- DPDT
 - SPDT
 
System Pressure
- bar: 1.4 to 12.4
 - kPa: 137.9 to 1,241
 - psi: 20 to 180
 
Temperature Effect
- Decreasing Set Point Shift: 5 psi/37.78° C (100° F) Average
 - Increasing Set Point Shift: 5 psi/37.78° C (100° F) Average
 - Set Point Shift: ± 1.5 inH₂O/37.78° C (100° F)