Model 10BP Precision Back Pressure Regulator
Brand: Fairchild Industrial Products- Control sensitivity of 1/8" water column
- High Flow Capacity
- Separate Control Chamber
- Aspirator Tube isolate the diaphragm from the main flow
- Unit construction
- Mounting Bracket available
Displaying prices & availability for in USD. Change location.
- Base Model - 1020
- Port Size - 1/4" NPT
- Port Thread - BSPP (Parallel)
- Elastomers - Fluorocarbon (Viton)
- Actuation Adjustment Means - Tamper Proof
Specifications
PRESSURE RANGE
- 0-2 psig, 0-0.15 bar, 0-15 kPa
- 0-10 psig, 0-0.7 bar, 0-70 kPa
- 0-20 psig, 0-1.5 bar, 0-150 kPa
- 0.5-30 psig, 0.03-2 BAR, 3-200 kPa
- 1-60 psig, 0.1-4 BAR, 10-400 kPa
- 2-150 psig, 0.1-10 BAR, 15-1000 kPa
- 3-200 psig, 0.2-14 BAR, 20-1400 kPa
- 5-300 psig, 0.3-21 BAR, 35-2100 kPa
- 5-400 psig, 0.3-28 BAR, 35-2800 kPa
Supply Pressure - Maximum
- bar: 35
- kPa: 3,500
- psig: 500
Trim Material
- Brass
- Zinc-Plated Steel
Output Options
- None
Mounting
- None
Elastomers
- Fluorocarbon (Viton)
- Nitrile on Dacron
- Silicone
Relief
- Relieving
Media
- Compressed Air
- Gas
Vent
- Straight
Actuator Type
- Knob Adjust
- Screwdriver Adjust
- Tamper-Proof
Environmental Protection
- Acceptable for Use in Zones 1 & 2 for Gas Atmosphere, Groups IIA & IIB & Zones 21 & 22 for Dust Atmospheres
NPT Connection
- 1/2" NPT Female
- 1/4" NPT Female
- 3/8" NPT Female
Ambient Temperature Range
- -40° to 93° C (-40° to 200° F)
Flow Capacity
- 40 scfm
- 40 scfm (68 m³/hour) at psig: 100 (bar: 7, kPa: 700) Supply & psig: 20 (bar: 1.5, kPa: 150) Set Point
- 68 m³/hour
Pressure Range
- bar: 0 to 1.36
- bar: 0 to 28
- bar: 0.034 to 2.04
- bar: 0.068 to 4.08
- bar: 0.136 to 10.20
- bar: 0.204 to 13.60
- bar: 0.34 to 27.20
- kPa: 0 to 137
- kPa: 0 to 2,800
- kPa: 13.6 to 1,020
- kPa: 20.4 to 1,360
- kPa: 3.4 to 204
- kPa: 34 to 2,720
- kPa: 6.8 to 408
- psi: 0.5 to 30
- psig: 0 to 20
- psig: 0 to 400
- psig: 1 to 60
- psig: 2 to 150
- psig: 3 to 200
- psig: 5 to 400
BSP Connection
- 1/2" BSPP Female
- 1/2" BSPT Female
- 1/4" BSPP Female
- 1/4" BSPT Female
- 3/8" BSPP Female
- 3/8" BSPT Female
Supply Pressure Effect
- < 0.007 bar
- < psi: 0.01 (bar: 0.0007, kPa: 0.7)
- < psig: 0.1 (bar: 0.007, kPa: 0.7)
- psig: 0.1 (bar: 0.007, kPa: 0.7) for a psig: 100 (bar: 7, kPa: 700) Change in Supply Pressure
Enclosure, Body Material
- Aluminum
Sensitivity
- < 1/8 inH₂O (0.32 cm)
The Model 10BP regulator ships from the factory, set at approximately midrange. When you install the regulator, use the Knob Assembly to set the required relief pressure, approximately. Full range setting requires about 13 to 16 turns, depending on the range of the unit. Turn the Knob Assembly slowly in a clockwise direction to increase the setpoint or back pressure. Turn the knob in a counterclockwise direction to decrease the setting.
The Model 10BP Regulator uses the force balance principle to open the Relief Valve and vent system pressure when the set point is exceeded.
Downstream pressure is transmitted through the Aspirator Tube to the bottom of the Diaphragm Assembly. When you adjust the range screw for a specific set point, the Range Spring compresses and exerts a force on the top of the Diaphragm Assembly. As long as the pressure acting on the bottom of the Diaphragm Assembly produces a force less than the spring force acting on the top of the Diaphragm Assembly, the Relief Valve remains closed. When system pressure increases, the force on the bottom of the Diaphragm Assembly increases until it reaches the set point. When system pressure increases beyond the set point, the assembly moves upward, lifting the Relief Valve from its seat and vents the downstream air.
If downstream pressure decreases below the set point, the assembly moves downward closing the Relief Valve.
For installation instructions, refer to the Fairchild Model 10BP Pneumatic Precision Back Pressure Regulator Installation, Operation and Maintenance Instructions, IS-100010BP.