PD6938-IS ProtEX+ Pulse Input Intrinsically Safe Flow Rate/Totalizer
Brand: Precision Digital CorporationThe PD6938 ProtEX+ pulse input flow rate/totalizers can be installed in a variety of areas (hazardous, dirty, wet, corrosive, hot, or cold) to provide convenient and informative display of flow rate and total from any pulse output flowmeter.
These instruments will accept a variety of pulse inputs, including slow pulse rates. They can be powered from a battery, 9-30 VDC, or the 4-20 mA output loop, have on-board datalogging capabilities, come with approvals for intrinsic safety, and can be ordered with optional 4-20 mA output and two relays.
The PD6938-IS is ATEX and IECEx Certified as Intrinsically Safe. It can operate down to -40°C and is certified by the agencies to be installed in areas that get as cold as -55°C. The display will cease functioning below -40°C but no damage will be done to the instrument.
One of the most convenient features of these instruments is their dual-line display, which is typically used to display the flow rate on the top display and flow total, flow grand total, or a tag on the bottom display. The top display has five characters and the bottom display has eight characters for clear indication of tags, units, or alarm messages.
Further enhancing the display on these instruments is a 20-segment bargraph and backlighting that can turn red during an alarm condition.
The PD6938 ProtEX+ is available in aluminum and stainless steel enclosures that are designed for easy use and installation. The process connection is available in M20, 3/4" NPT and 1" NPT and there are two other conduit holes for field wiring.
Field wiring is made to removable screw terminals and the display module can be oriented in 4 different positions to accommodate different mounting configurations and requires no tools to install. The display has been designed to optimize viewing angle.
- Fully-Approved Intrinsically Safe Pulse Input Flow Rate/Totalizers
- NPN Open Collector, PNP, TTL, Switch Contact, Sine Wave (Magnetic Pickup Coil), or Active Square Wave Inputs
- Top Display: Five 12-Segment Alphanumeric Characters, 0.7" (17.8 mm)
- Bottom Display: Eight 14-Segment Alphanumeric Characters, 0.4" (10.2 mm)
- Display Mountable at 0°, 90°, 180°, & 270° (No Tools Required)
- CapTouch Through-Glass Button Programming with Normal and Delayed Modes
- Red Backlight for Alarm Conditions, Enable and Disable Backlight from Menu
- 8-Digit Total & Grand Total Display, Up to 13 Digits Using Both Lines
- Display Rate & Total Simultaneously
- Bi-Directional Flow Detection Via Digital Input
- Non-Resettable Grand Total
- Display Previous Total and Previous Grand Total with Time-of-Day Reset Feature
- Reset Total / Grand Total with CapTouch Button, Digital Input, or Time-of-Day Feature
- Automatic or Manual Batch Control
- K-Factor Calibration or Scaling with Up to 32-Point Linearization
- Gate Function for Rate Display of Slow Pulse Rates
- (2) Open Collector Outputs Standard; Assignable to Pulse, Alarm, Timer, or Stopwatch
- (2) Optional Solid-State Relays; Assignable to Alarm, Sample, Timer, Batch Control, or Stopwatch
- Optional Isolated 4-20 mA Analog Output
- Free PC-Based MeterView XL USB Programming Software
- 9-30 VDC, Battery, or 4-20 mA Output Power Options
- Battery-Powered Momentary Backlight & Display Sleep and Off Modes to Extend Battery Life
- Modbus RTU RS-485 Communications Standard on DC & Battery Powered Models
- On-Board Data Logging of up to 2,032 Records and Modbus Accessible Data
- Password Protection for Settings, Total & Grand Total
- ATEX and IECEx Certified as Intrinsically Safe
- Operating Temp Range: -40 to 75°C (-40 to 167°F)
- Installation Temp Range: -55 to 75°C (-67 to 167°F)
- Conformal Coated PCBs for Dust & Humidity Protection
- Flange for Wall or Pipe Mounting; Loop for Stainless Steel Tag; Holes for Tamper-Proof Seal
- Explosion-Proof Aluminum & Stainless Steel Enclosures with 1", 3/4", or M20 Connections
- 3-Year Warranty
Specifications
Display
- Dual-line LCD with backlight
- Both lines alphanumeric
- Top: 0.7" (17.8 mm) 5 digits, 12-segment
- Bottom: 0.4" (10.2 mm) 8 characters, 14-segment
- Display may be programmed to turn red and flash a user-defined message on alarm condition
Top Display
- 5 digits (-9999 to 99999) or 5 characters (all capital & most lower-case letters)
Bottom Display
- 8 digits (-9,999,999 to 99,999,999; separated by commas) or 8 characters (all capital & most lower-case letters)
Programming Method
- Four CapTouch through-window buttons when cover is installed
- The CapTouch buttons can be used with the cover removed. Free PC-based USB MeterView XL programming software
Environmental
- Operating temperature range: -40 to 75°C (-40 to 167°F)
- Storage temperature range: -55 to 85°C (-67 to 185°F)
- Installation temperature range: -55 to 75°C (-67 to 167°F) (The display ceases to function, however inputs and outputs continue to operate)
- Relative humidity: 0 to 90% non-condensing
- Printed circuit boards are conformally coated
Connections
- Removable screw terminal blocks
- Display terminals: accept 16 to 30 AWG wire
- Relay terminals: accept 12 to 26 AWG wire
- 4-20 mA output: accept 16 to 30 AWG wire
Material of Construction
- AL Models: ASTM A413 LM6 die-cast aluminum, copper-free, enamel coated
- SS Models: ASTM A743 CF8M investment-cast 316 stainless steel
- Window: Borosilicate glass
- Gasket: Fluoroelastomer
Accuracy
- 4-20 mA Transmitter Output: ±0.05% FS ±0.001mA
- Input - Rate: ±0.02% of calibrated span ±1 count
- Input - Total: Every input pulse is counted
Overall Dimensions (W x H x D)
- 5.25" x 5.65" x 4.80" (133 x 144 x 122 mm)
Weight
- Aluminum: 4.8 lbs (2.18 kg)
- Stainless Steel: 9.0 lbs (4.08 kg)
Approvals
- ATEX & IECEx
- CSA
- EMC
- CE