101/121 Big Hermet – Hermetically Sealed Differential Pressure Switch

Brand: SOR Inc

The SOR hermetically sealed, Big Hermet differential pressure switch is designed for mounting in a panel or on the wall when easy access is critical or you don’t want the switch right at the source of the pressure.

 This versatile differential pressure switch uses a switching element that is hermetically sealed in a steel capsule, making it perfect for a wide variety of applications.

101/121 differential pressure switches are rugged, field-mounted instruments that incorporate a flexible modular design providing cost effective sensing solutions. 
 
The two-piece piston design allows for complete differential pressure reversal without damage.
Features
  • Modular Design - Wide range of electrical enclosures available.
  • Robust Construction
    • Rugged, high cycle rate tolerance, long life, not critical to vibration, high overrange and proof pressures, withstands full Hi and Lo side pressure reversals, excellent corrosion resistance to hostile environments.
  • Instrument Quality - High repeatability, narrow dead band, negligible temperature effect and static influence.
  • Wetted Parts - Wide selection of materials.
  • Field Adjustable
    • Excellent resolution of Set Points, adjustment, no special tools required
    • No-charge factory calibration
  • Agency Listings/Certification
    • Select models with ATEX, IECEx, CSA, INMETRO and UL
    • Meets most code and customer requirements
  • Safety Certified to IEC 61508 (SIL) 
    • SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528)
  • Delivery
    • Routine shipments 7 to 10 working days
    • Emergency shipments via air same day
  • Service - Factory service engineers and area factory representatives provide effective and prompt worldwide service.
  • Warranty - 3 years from date of manufacture.

Specifications

Brand

Electrical Rating

  • 0.25 A at 250 Vdc Resistive
  • 0.3 A at 125 Vdc, Resistive
  • 0.4 A at 125 Vdc, Resistive
  • 0.5 A at 125 Vdc, Resistive
  • 1 A at 28 Vdc, Resistive
  • 1 A at 30 Vdc, Resistive
  • 5 A at 30 Vdc, Resistive
  • 7 A at 30 Vdc, Resistive
  • 10 A at 30 Vdc, Resistive
  • 15 A at 250 Vac
  • 5 A at 250 Vac
  • 1 A at 125 Vac
  • 7 A at 250 Vac
  • 11 A at 250 Vac

Electrical Connection & Type

  • 18" 18 AWG Color-coded Wire Leads Except When Terminal Blocks are Specified - All Other Switching Elements
  • Screw Terminal - Switching Elements K, KA, G, L, C, N, Y & W
  • Connection Size: 3/4” NPT(F)
  • Connection Size: 1/2” NPT(M)

Environmental Protection

  • Explosion-proof
  • Hazardous Area
  • Non-Hazardous Area
  • NEMA 1
  • NEMA 4
  • NEMA 4X
  • IP65

Switch Type

  • DPDT
  • SPDT

Ambient Temperature

  • -54° to 104° C (-65° to 400° F)

Process Connection Material

  • Pressure Port: 316 Stainless Steel; CF-8M Cast Alloy

Electrical Contacts

  • Lower Power & Hermetically Sealed Gold Contacts
  • Normally Closed
  • Normally Open

O-Ring Material

  • Buna-N with Allowable Temperature -34° to 93° C (-32° to 200° F)
  • Viton with Allowable Temperature 0° to 204° C (32° to 400° F)

Diaphragm Material

  • 316 Stainless Steel
  • Hastelloy B
  • Viton
  • Teflon-Coated Polyimide (TCP)

Gasket Material

  • Viton
  • Cover Gasket: Neoprene

Set Point - Decreasing

  • bar: 0.2 to 34.5
  • kPa: 20 to 3450
  • psi: 3 to 500

Set Point - Increasing

  • bar: 0.2 to 34.5
  • kPa: 20 to 3450
  • psi: 3 to 500

Pressure Range

  • 3 to 500 psid

Typical Dead Band

  • 0.5 to 20 psi

Housing Material

  • Aluminum
  • Cast Iron

Approvals & Certifications

  • ATEX Ex db IIC T6/T5 Gb, II 2 G EEx M II
  • CRN - Canadian Registration Number
  • CSA: for Hazardous Locations Class I, Grade A, B, C, D, Class II, Groups E, F, G, Divisions 1 & 2
  • IECEx db IIC T6/T5 Gb
  • INMETRO Ex db IIC T6/T5 Gb
  • TestSafe: for Hazardous Locations Ex S Zone 2 IIC T4 IP65, Ex TD A22 T105° C IP65
  • UL: for Hazardous Locations Class I, Grade A, B, C, D, Class II, Groups E, F, G, Divisions 1 & 2
  • SAA
  • SIL

Cover Material

  • Aluminum - Housing Model TA

  • Fluid Power Applications
  • Low to High Differential Pressure
  • Process Applications

show more