Q46CT Toroidal Conductivity Monitor

Brand: Analytical Technology Inc

The Model Q46CT Conductivity monitor/analyzer provides a versatile system for monitoring and control of conductivity over a range of 1 µS/cm to 2.000 Siemens/cm. 

The display may be programmed for ranges of 0-2000 uS, 0-2.000 mS, 0-20.00 mS, 0-200 mS, 0-2000 mS, or 0-2.000 S. 

A lower line display indicates the equivalent TDS value in mg/l, using a user programmable conversion factor. 

Q46CT monitors use a toroidal conductivity sensor that measures conductivity inductively. 

This type of sensor is particularly well suited to measurements in solutions that contain materials that would foul a normal conductivity sensor. It is very good for high conductivity measurements, but should not be used if normal conductivity is below 100 uS.
Features
  • Adaptable concentration version for direct display of chemical concentrations.
  • Extra Outputs – Expansion board to add a third analog output or three additional non-isolated low power relays.
  • AC or DC Power Options
  • Flexible, programmable range options from 0-200 PPB up to 0-200 PPM provide maximum application flexibility.
  • AC or DC Power Options
  • 3 Analog Output Options for conductivity and temperature.
  • PID Output
  • Digital Communications available in either Profibus-DP, Modbus-RTU or Ethernet-IP.
  • Relay Assignable – Three SPDT relays are standard, with three additional low power relays available as an option.
  • Flexible Mounting
  • Large, back-lit, LCD Display

Specifications

Display Range

  • 0-200.0 µS, 0-2.000 / 20.00 / 200.0 / 2000 mS, 0-2.000 S

Accuracy

  • 0.5 % of Selected Range or 0.02 ppm

Repeatability

  • 0.3 % of Selected Range or 0.01 ppm

Non-Linearity

  • 0.1 % of Selected Range

Temperature Drift

  • 0.01 % of Span/°C

Power

  • 100-240 Vac, ± 10 %, 50/60 Hz
  • 12-24 Vdc, 500 mA max

Analog Outputs

  • Two Isolated 4-20 mA, 500 Ω Load Max. (3rd Output Optional)

Relays

  • Three SPDT, 6A @ 250 Vac, 5A @ 24 Vdc (3 Additional SPST Non-Isolated, 1A @ 30 Vdc Optional)

Display

  • 4-Digit, 0.75” Numeric LCD with 12-Digital Second Line, LED Back Light.

Enclosure

  • NEMA 4X Polycarbonate V-0 Flammability

Operating Conditions

  • -20 to 60° C (-4 to 140° F)

Weight

  • 6 lbs (2.7 kg) with Sensor, Flowcell and Accessories

Sensitivity

  • 0.05 % of Span or 0.01 mS

Digital Output

  • Profibus DP, Modbus RTU or Ethernet IP

Mounting

  • Wall Mounting Kit Standard, Panel Mount Bracket and Pipe U-Bolts Available

Size

  • 5.6” W x 4.9” H x 6.4” D

Sensor Type

  • Toroidal (Inductive)

Sensor Materials

  • Noryl

Sensor Cable Length

  • 20 ft (6 m) Standard, 200 ft (61 m) Max. with Junction Box

Sensor Temperature Limits

  • 0-105° C, 0-80° C with Flowcell

Sensor Pressure Limit

  • 150 psig max

Sensor Connection

  • 3/4” MNPT Rear Thread

Sensor Flowcell

  • 2” CPVC with Alignment Key

Sensor Temperature Element

  • Pt1000 RTD

  • High Conductivity Processes
  • High Solids Content Processes
  • Pharmaceutical Applications
  • Fume Scrubbers
  • Boiler Blowdown
  • Cooling Towers
  • Chemical Feed
  • Food and Beverage
  • Metal Plating / Rinsing
  • Bioremediation
  • Clean-In-Place
  • Potable Water
  • Wastewater Treatment
  • Pulp and Paper
  • Textile Manufacturing
  • Neutralization Tanks
  • Refining
  • Acid / Caustic Feed

show more