EC80 Flow Processor
Brand: Badger MeterThe Cox EC80 Flow Processor is a programmable electronic processor, providing total compensation to enhance flow meter accuracy, while extending the linear flow range.
Packaging is provided for remote, direct or embedded mounting to support most installation or application requirements.
The compact design includes both single and dual frequency inputs from 4 or 10 ohm pickups, as well an RTD input and an additional analog input for other temperature inputs.
The EC80 processor tracks all variables to compensate for viscous and inertial effects, using proven Strouhal-Roshko algorithms.
Enhanced DSP technology allows for exceptional signal characterization using a 32-bit floating point processor at 150 MHz, capable of producing a 100 microsecond speed of response.
Features
- Enhanced low-flow resolution and output smoothing
- Dynamic response to changing conditions with fully compensated output
- Easily interfaces to data acquisition or control system
- No need for additional amplifiers or signal conditioners, yielding cost savings
- User assigned output variables allows for greater ease of system integration
- Provides Total Compensation
- Enhances Flow Meter Accuracy
Specifications
Brand
Input Power
- Nominal: 24 Vdc, 2 W max.
- With Digital Output: 7-32 VDC
- With Analog Output: 12-32 VDC
Frequency Output
- 0-5 V, TTL, 1 to 20,000 Hz, Square Wave
Operating Temperature
- -40° to 185° F (-40° to 85° C)
Storage Temperature
- -67° to 257° F (-55° to 125° C)
Humidity
- 0 to 80% RH, Non-condensing
Enclosure
- Aluminum
- NEMA 4 (IP65)
Display
- 8 digits, 0.46" (11.7 mm) high digits, transmissive LCD with green/red LED backlight
Remote Cable Length
- Flow Meter to EC80: 10 ft (3 m)
- EC80 to DAQ or Control System: 100 ft (30.5 m)
- Aviation & Aerospace
- Refining, Chemical & Petrochemical
- Process & General Industry
- Test Equipment & Services
Documentation
Review this product and let us know your experiences
Write a Review