E-Series Ultrasonic Plus Meters
Brand: Badger MeterThe E-Series® Ultrasonic Plus meter utilizes ultrasonic transit-time technology to measure cold potable water and incorporates an integrated valve into the lay length of the meter.
This valve feature allows water utilities to actuate the valve remotely to temporarily restrict water service safely and efficiently.
Features
- Delivers precision accuracies with extended flow ranges
- Gate valve integrated into standard lay length of meter - no cut-ins required
- Patented magnetically coupled valve to extend field life (US Patent No. 10,161,777.B2)
- Patented flow restriction valve technology supports open, restricted and partially restricted options (US Patent No. 8,539,827)
- Does not require infrastructure
- Valve position-indicating LED
- Fully submersible - electronics completely encapsulated to withstand harsh, flooded pit environments
- Low pressure loss
- Easy-to-read, 9-digit display presents consumption, rate of flow, reverse flow indication and alarms
- High resolution industry standard ASCII encoder protocol
Specifications
Brand
Meter Size
- 5/8" x 3/4" (15 mm)
- 3/4" (20 mm)
Temperature Range
- 1° to 60° C (34° to 140° F)
Flow Range
- 0.05 to 32 gpm (0.01 to 7.27 m³/hr)
Accuracy
- ±1.5% over the normal flow range
- ±3.0% from the extended low flow range to the minimum flow value
Storage Temperature
- -40° to 60° C (-40° to 140° F)
- Maximum Ambient Storage (Storage for One Hour): 150° F (66° C)
Humidity
- 0 to 100% Condensing; meter is capable of operating in fully submerged environments
Material of Construction
- Meter Housing & Valve Bonnet: Lead-free Bronze Alloy
- Bonnet Seal: EPDM O-ring
- Power Control Module Housing: Engineered Polymer
- Register Housing: Engineered Polymer
- Gate: Engineered Polymer
- Power Screw: 316 Stainless Steel
- Customer Water Usage
Review this product and let us know your experiences
Write a Review