Temperature Switch

Brand: SOR Inc

The SOR Temperature Switch utilizes a vapor-pressure thermal system. Fluid vapor pressure changes predictably according to the influence of temperature on the sensing bulb.

Process temperature changes cause proportional vapor pressure changes in the temperature sensing bulb that act on the diaphragm/piston assembly to actuate and deactuate a snap-action electrical switching element at discrete process temperatures.

The instrument’s behavior is determined by the vapor pressure principle.
Features
  • Robust construction
  • Vapor pressure principle
  • Vapor fill fluid
  • Direct immersion temperature sensing bulbs
  • Remote mount sensing bulbs
  • Snap-action electrical switching element
  • Shock / vibration
  • Factory calibration
  • Agency listings/certification
  • Safety certified to IEC 61508 (SIL)

Specifications

Brand

Adjustment Type

  • Set Point Adjustment

Ambient Temperature Range

  • -54° to 200° C (-65° to 400° F)

Approvals & Certifications

  • ATEX EEx d IIC T6 & T5
  • CRN
  • CSA Certified Explosion-proof Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class III, Divisions 1 & 2
  • GOST-R
  • IECEx Certified (Ex db IIC T6/T5 Gb)
  • INMETRO
  • Rostechnadzor (RTN)
  • UL Ex ia IIC T6 to T4 Gb

Approvals & Certifications

  • Calibration
  • Compliance/Conformance
  • Dielectric Test
  • IEC 61508 for Non-Redundant use in SIL 1 & SIL 2
  • Inspection Report
  • Typical Material of Wetted Parts

Capillary Length

  • 6 to 20 feet (1.8 to 6 metres)

Capillary Material

  • 316 Stainless Steel

Conduit Connection

  • 3/4” NPT Female
  • Potted Wire Leads 1/2”Male NPT

Diaphragm Material

  • 316 Stainless Steel
  • Hastelloy B
  • Hastelloy C
  • Monel

Electrical - Free Leads

  • 18” Free Wire Leads for 90° Conduit Block

Electrical Connectors

  • 18” Free Wire Leads
  • 3/4” NPT Female
  • 90° Conduit Block 1/2” NPT Male
  • M20 x 1.5
  • Standard Terminal Block

Electrical Contacts

  • Gold-Plated
  • Normally Closed
  • Normally Open

Electrical Rating

  • 1-15 A at 125-250 Vac
  • Resistive: 0.25-10 A at 28-250 Vdc

Enclosure Finish

  • Covers Exterior & Interior Except Working Parts: Fungicidal Varnish
  • Epoxy Coated (Polyamide Epoxy with 316 Stainless Steel Pigment)

Enclosure, Body Material

  • 316 Stainless Steel
  • Carbon Steel
  • Cast Iron
  • Series 2000, Copper-Free Aluminum

Environmental Protection

  • Explosion-proof Class I, Groups C & D, Class II, Groups E, F, G, Divisions 1 & 2
  • IP10
  • IP65
  • IP66
  • NEMA 1
  • NEMA 4
  • NEMA 4X
  • NEMA 7
  • NEMA 9
  • Weatherproof

Gasket Material

  • Neoprene Cover Gasket
  • Viton

Materials of Construction

  • Armor: 300 Series Stainless Steel
  • Universal Terminal Box: Stainless Steel

Maximum System Pressure

  • psi: 1,000 to 2,300 (kPa: 6,895 to 15,860, bar: 68.9 to 158.6)

Mounting

  • Direct Mounting
  • Panel Mounting
  • Pipe (Stanchion) Mounting
  • Remote Mounting

NACE & NIST

  • NACE MR-0175

Name Plate, Tag Material

  • Fiber
  • Stainless Steel

NPT Connection

  • 1/2” NPT Male

Override

  • Manual Reset

Pressure Range

  • Maximum

Repeatability

  • 1 % of Full Scale
  • 2 % of Full Scale

Set Point - Decreasing

  • -45° to 540° C (-50° to 1,000° F)

Set Point - Increasing

  • -45° to 540° C (-50° to 1,000° F)

Shock

  • MIL-S-901D

Spring Material

  • Elgiloy

Switch Type

  • DPDT
  • SPDT

Vibration

  • MIL-S-901D

Documentation

show more