Dual Hi-Lo Pressure Switch

Brand: SOR Inc

Dual Hi-Lo Pressure Switches are rugged, field-mounted instruments.

The pressure sensing assemblies are conventional Static “O” Ring type.

The main difference is that two sensing assemblies share a common process pressure port, housing and electrical conduit connection. 

Two discrete sensing assemblies provide independently adjustable, fine resolution Set Points that can be calibrated to the same actuation point, or split to the full span of the adjustable  range without interaction.

Features
  • Robust Construction - High cycle rate tolerance, long life, not critical to vibration.
  • Instrument Quality - High resolution of Set Points, high repeatability, narrow dead band, negligible temperature effect, high overrange and proof pressures, exceptionally long service life.
  • Field Adjustable Set Points - Full range adjustability. No-charge factory calibration.
  • Cost Effective - Simple, fast installation without special tools, long service life, no required periodic service or spare parts. Installation of one Dual Hi-Lo provides two pressure switches in the time normally required for the installation 
    of one pressure switch.
  • Safety Certified to IEC 61508 (SIL) -  SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product.
  • Built-in Quality - Rigid quality standards maintained from raw material to finished product.
  • Delivery - Routine shipments 7 to 10 working days. Emergency shipments via air within one day.
  • Service - Factory service engineers and area factory representatives provide effective and prompt worldwide service.
  • Warranty - 3 years from date of manufacture.

Specifications

Brand

Adjustment Type

  • Field Adjustable Set Points

Ambient Temperature Range

  • -34° to 80° C (-30° to 180° F)

Approvals & Certifications

  • ATEX II 2 G EEx M II, Db IIC T5/T6 Gb
  • CRN - Canadian Registration Number
  • CSA Hazardous Locations Class I Groups A, B, C, D, Class II Groups E, F, G, Divisions 1 & 2
  • FM
  • IEC 61508
  • RTN
  • SAA
  • TestSafe Hazardous Locations Ex S IIC T6 IP65 Class I, Zone 1 DIP T6 IP65
  • UL Hazardous Locations Class I Groups A, B, C, D, Class II Groups E, F, G, Divisions 1 & 2

Conduit Connection

  • Electrical: 3/4" NPT Female

Deadband

  • Typical psi: 0.2 to 98 (kPa: 1.4 to 700, bar: 0 to 7) - K Switch
  • Typical psi: 0.6 to 294 (kPa: 4.13 to 2,027, bar: 0.04 to 20.27) - EF Switch

Diaphragm Material

  • 316L Stainless Steel
  • Buna-N
  • Carpenter 20 Stainless Steel / Alloy 20 or Incoloy
  • Ethylene Propylene (EPR)
  • Hastelloy B
  • Hastelloy C
  • Kalrez
  • Monel
  • Neoprene
  • Tantalum
  • Teflon-Coated Polyimide (TCP)
  • Viton

Electrical - Free Leads

  • 18", 18 AWG Wire Leads

Electrical Connectors

  • 1/2" NPT Female
  • 3/4" NPT Female
  • M20 x 1.5 Female
  • Terminal Block, 6-Place Compression & Screw Typical

Electrical Contacts

  • Lower Power Gold Contacts
  • Normally Closed
  • Normally Open

Electrical Rating

  • 0.3 A at 125 Vdc, Resistive - High Ambient Temperature Rating 204.4° C (400° F)
  • 0.4 A at 125 Vdc, Resistive - Normal Service AC, Wide Adjustable Dead Band
  • 0.5 A at 125 Vdc, Resistive - Wide Dead Band AC & DC, AC or DC, Narrow Dead Band DC, Very Wide Dead Band DC, High Ambient Temperature Rating 204.4° C (400° F), Hermetically Sealed Switching Element
  • 1 A at 125 Vac - Low Power Gold Contacts, Hermetically Sealed Switching Element
  • 1 A at 28 Vdc, Resistive - Low Power Gold Contacts
  • 1 A at 30 Vdc, Resistive - Low Power Gold Contacts, Hermetically Sealed Switching Element
  • 1.5 A Min. at 125 Vdc, Resistive - Very High Capacity DC Magnetic Blow-Out
  • 10 A at 125 Vac - Very High Capacity DC Magnetic Blow-Out
  • 10 A, Max.
  • 11 A at 250 Vac - AC or DC, Hermetically Sealed Switching Element
  • 15 A at 250 Vac - Normal Service AC, Wide Dead Band AC & DC, Very Wide Dead Band DC, Wide Adjustable Dead Band
  • 5 A at 250 Vac - Narrow Dead Band DC, High Ambient Temperature Rating 204.4° C (400° F), Hermetically Sealed Switching Element
  • 5 A at 30 Vdc, Resistive - Normal Service AC, AC or DC, Narrow Dead Band DC, Hermetically Sealed Switching Element

Enclosure Finish

  • Epoxy Coated (Exterior Only)
  • Epoxy Powder-Coated
  • Fungicidal Varnish (Covers Exterior & Interior Except Working Parts)

Enclosure, Body Material

  • Copper-Free Aluminum Alloy 356

Environmental Protection

  • IP65
  • IP66
  • NEMA 4
  • NEMA 4X

Mounting

  • Pipe Mounting Kit for 1-1/2 to 2" Pipe

Name Plate, Tag Material

  • Stainless Steel
  • Fiber

NPT Connection

  • 1/2" NPT Female
  • 1/2" NPT Male
  • 1/4" NPT Female
  • 1/4" NPT Male

O-Ring Material

  • AFLAS
  • Buna-N
  • Ethylene Propylene (EPR)
  • FFKM
  • Kalrez
  • Neoprene
  • Viton
  • Viton GLT

Overpressure & Static Pressure Limits

  • Overpressure psi: 750 to 4,600 (kPa: 5,000 to 32,000, bar: 50 to 320)

Piston Material

  • Stainless Steel for Corrosion Resistance

Process Connection Material

  • Pressure Port Material: 316 Stainless Steel, CF-8M Casting
  • Pressure Port Material: Aluminum Alloy 356 Copper-Free Casting

Proof Pressure

  • psi: 1,000 to 4,600 (kPa: 7,000 to 32,000, bar: 70 to 320)

Set Point - Decreasing

  • bar: 0.14 to 275
  • inHg: -30 to 15
  • kPa: 14 to 27,500
  • psi: 2 to 4,000

Set Point - Increasing

  • bar: 0.14 to 275
  • inHg: -30 to 15
  • kPa: 14 to 27,500
  • psi: 2 to 4,000

Special Cleaning & Packaging

  • Wetted Parts are Cleaned for Oxygen Service

Switch Type

  • DPDT
  • SPDT

System Pressure

  • bar: 0.138 to 317.2
  • kPa: 13.79 to 31,716
  • psi: 2 to 4,600

  • Alarms
  • Control Applications
  • Safety Shutdown Applications

show more