Approvals & Certifications
Hazardous Areas
- Acceptable in Zones 1–2 (gas, Groups IIA & IIB) and Zones 21–22 (dust).
Max. Supply Pressure
- 250 psig : 17.0 bar : 1700 kPa
Max. System Pressure
- 250 psig : 17.0 bar : 1000 kPa
Flow Capacity
- 150 scfm (255 m³/hr) @ 100 psig : 7.0 bar : 700 kPa supply & 20 psig : 1.5 bar : 150 kPa setpoint.
Max. Signal or Output Pressure
- 150 psig : 10 bar : 1000 kPa
Actuator Adjustment Type (for Output Pressure)
Ambient Temperature Limits
- -40° F to +200° F (-40° C to 93.3° C)
Elastomers Material
- Nitrile
- Viton (Fluorocarbon)
BSP Connection
- 1/2" BSPP Female
- 1/2" BSPT Female
- 3/4" BSPP Female
- 3/4" BSPT Female
- 3/8" BSPP Female
- 3/8" BSPT Female
Supply Pressure - Maximum
- bar: 17
- kPa: 1,700
- psig: 250
Environmental Protection
- Acceptable for use in Zones 1 & 2 for Gas Atmosphere, Groups IIA & IIB & Zones 21 & 22 for Dust Atmospheres
Flow Capacity
- 150 scfm (255 m³/hour) at psig: 100 (kPa: 700, bar: 7) System Pressure
NPT Connection
- 1/2" NPT Female
- 3/4" NPT Female
- 3/8" NPT Female
Ratio Accuracy
- 3.0 % at psig:100 (kPa:700, bar:7) Input Span
Ambient Temperature Range
- -40° to 93.3° C (-40° to 200° F)
Signal or Output Pressure - Maximum
- psig: 150 (kPa: 1,000, bar: 10)