Approvals & Certifications
Hazardous Areas
- Acceptable in Zones 1–2 (gas, Groups IIA & IIB) and Zones 21–22 (dust).
Max. Supply Pressure
- 250 psig : 17.0 bar : 1700 kPa
Max. Output Pressure
- 50 psig : 3.5 bar : 350 kPa
- 75 psig : 5.0 bar : 500 kPa
- 150 psig : 10.0 bar : 1000 kPa
Flow Capacity
- 150 scfm (255 m³/hr) @ 100 psig : 7.0 bar : 700 kPa supply & 20 psig : 1.5 bar : 150 kPa setpoint.
Set Point
- 1" (2.54 cm) W.C.
- 2" (5.08 cm) W.C.
- 3" (7.62 cm) W.C.
Exhaust Capacity
- 40 scfm (65 m³/hr) where downstream pressure is 5 psig : 0.35 bar : 35 kPa above 20 psig : 1.5 bar : 150 kPa setpoint.
Ambient Temperature Limits
- -40° F to +200° F (-40° C to 93.3° C)
Supply Pressure - Maximum
- bar: 17
- kPa: 1,700
- psig: 250
Exhaust Capacity - Relieving Units Only
- 40 scfm
- 40 SCGM (65.2 m³/hour) where Downstream Pressure is psig: 5 (bar: 0.35, kPa: 35) Above psig: 20 (bar: 1.5, kPa: 150) Set Point.
- 65.2 m³/hour
Trim Material
- 316 Stainless Steel
- Brass
- Zinc-Plated Steel
Ambient Temperature Range
- -40° to 93° C (-40° to 200° F)
Environmental Protection
- Acceptable for use in Zones 1 & 2 for Gas Atmosphere, Groups IIA & IIB & Zones 21 & 22 for Dust Atmospheres
NPT Connection
- 1/2" NPT Female
- 3/4" NPT Female
- 3/8" NPT Female
Supply Pressure Effect
- bar: 0.007 to 0.021
- kPa: 0.7 to 2.1
- psig: 0.1 to 0.3
BSP Connection
- 1/2" BSPP Female
- 1/2" BSPT Female
- 3/4" BSPP Female
- 3/4" BSPT Female
- 3/8" BSPP Female
- 3/8" BSPT Female
Output Pressure - Maximum
- bar: 10
- kPa: 1,000
- psig: 150
Flow Capacity
- 150 scfm (255 m³/hour)
- 150 scfm (255 m³/hour) at psig: 100 (bar: 7, kPa: 700) Supply & psig: 20 (bar: 1.5, kPa: 150) Set Point
- 255 m³/hour
Elastomers
- Fluorocarbon (Viton)
- Nitrile on Dacron